Dimension (GD)
0.254mm [0.010 inch]
Note: Identify re-ground valve seats.
Install the valves in their designated location and
measure the depth.
Caution: Replace the valve if the depth is over the
limit.
Check valve depth (C).
Valve Depth
Min
Max
0.99mm
1.52mm
[0.0389 in]
[0.0598 in]