LO 10-3950-206-12
NOTES:
1.
FOR OPERATION OF EQUIPMENT IN
in neutral, add oil to bring oil level to "FULL" mark.
Operate for 5 minutes and check for leaks.
PROTRACTED COLD TEMPERATURES BELOW -15F
(-26C).
Remove lubricants prescribed in Key for
8. TRANSMISSION OIL FILTER. Each 500 hours,
temperatures above -15F (-26C). Relubricate with
remove filter element, clean filter housing, install new
lubricants specified in Key for temperatures below -15 F
filter element and seal. After replacement with engine
(-26C).
If OEA lubricant is required to meet the
running at idle speed, oil at operating temperature and
temperature ranges prescribed in the Key, OEA lubricant
transmission in neutral, add oil to bring oil level to
is to be used in place of OE/HDO-10 .lubricant for all
"FULL" mark. Operate for 5 minutes and check filter
temperature ranges where OE/HDO-10 is specified in
housing for leaks.
9. HYDRAULIC RESERVOIR LEVEL PLUG. To check
2. OIL CAN POINTS. Each 250 hours, lubricate
level, raise floor board and remove plug, oil should
controls, door hinges, linkage, pins, springs, latches, and
appear at plug opening.
all exposed adjusting threads with OE/HDO.
10. HYDRAULIC RESERVOIR OIL FILTER. Each 500
3. ENGINE OIL LEVEL HOT OR COLD CHECK. Cold
hours, remove filter element, clean filter shell and install
engine, oil level should be at high mark on dipstick. Hot
new filter element. After replacement, operate hydraulic
engine, oil level must be between high and low marks on
system for 5 minutes, check for leaks, check oil level and
dipstick (allow to set 5 minutes before checking).
bring to "FULL" mark.
4. ENGINE. Oil is to be changed each 250 hours.
11. HYDRAULIC RESERVOIR. Each 500 hours, drain
Drain when lubricant is warm.
reservoir, remove, clean and install strainer.
Fill
reservoir, operate hydraulic controls, check for leaks,
5. ENGINE OIL FILTER. Each 250 hours, remove filter
check oil level and bring to "FULL" mark.
element, clean housing and install new filter element.
After installing new filter element, fill crankcase, operate
12. WINCH. It is necessary to unreeve the hoist cable
engine for 5 minutes, check housing for leaks, check
to expose the winch drain and fill plugs located on face
crankcase oil level and bring to "FULL" mark.
of drum.
6. AIR CLEANER. Each 50 hours, refill reservoir to
13. WINCH. Check level each 1000 hours. Change
level mark. Each 250 hours disassemble entire unit,
gear lubricant only when required by maintenance repair
clean, re-oil and assemble.
After refill, operate for five minutes, check for leaks and
7. TRANSMISSION AND CONVERTER. Check oil
bring oil level to level plug opening.
level each 50 hours with engine running at idle speed, oil
at operating temperature and transmission in neutral.
14.
DRIVE AXLE.
Check level each 250 hours.
Maintain oil level to "FULL" mark. Change oil each 1000
Change gear lubricant only when required by
hours. Fill transmission to low mark. Run engine at idle
speed to fill converter and lines. With engine running at
other foreign material. After refill, operate for 5 minutes,
idle speed, oil at operating temperature and transmission
check for leaks and bring oil to level of fill and level plug
opening.
TA 220156
CARD 6 OF 7