Figure 3-69. Battery and Battery Box removal and installation
(winterized units)..
circuit.
b. On Equipment Test.
(1) Disconnect battery cables and tie back to prevent accidental flash current.
(2) Tag accurately for position, then remove all electrical leads from alternator.
(3) Use automotive generator and voltage regulator test set and hook up as illustrated in figure 3-73.
(4) Operate the alternator at approximately 2,500 RPM.