TM 5-3810-231-12
Figure 88. Swing controller assembly shown with cover removed.
(1) Clean the exterior with a cloth
Measure ohms from terminal A to B with an ohmmeter.
dampened with an approved cleaning
The reading should register 40 ohms. If not, replace
solvent.
plug-in voltage regulator unit.
(2) Inspect for cracks, breaks, or other
b.
Removal.
Remove the control cabinet
damage. Repair or replace a defective
control cabinet.
c.
Cleaning and Inspection.
d.
Installation. Install the control cabinet as
117