Fig. 2 - Rework Former Plunger and Cap
LIMITING SPEED MECHANICAL GOVERNOR (Fast Idle Cylinder)

Maintenance Manual For Crane, Truck Mounted Hydraulic 25 Ton (CCE) - Vol 3 Page Navigation
  215    216    217    218    219  220  221    222    223    224    225  
img
. . . .
TM 5-3810-300-24&P-3
Variable-Speed Limiting Speed Governor 2.7.1.3
7.  Thread the idle speed adjusting lock nut on the
after the governor adjustments (Section 14.3.3) have
threaded  end  of  the  high-speed  spring  plunger
been performed.
approximately 1/2 ".
8.  Screw the adjusting shaft into the adjusting shaft
Install Governor
retainer all the way in as shown in Fig. 1.
9.  Install the adjusting retainer and shaft onto the high-
Install the governor as outlined in Section 2.7.1, then
speed spring plunger. Turn down the adjusting retainer
connect the manual control flexible shaft to the governor
against the idle speed adjusting lock nut.
spring housing (Fig. 1).
10. Install the adjusting coupling and spring housing
Adjust the governor as outlined in Section 14.3.3.