TM 5-3810-306-20
TABLE 3-1. ORGANIZATIONAL TROUBLESHOOTING (CONTD)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
52. HOIST WILL NOT RAISE LOAD
Step 1.
Broken hydraulic lines or fittings.
a. Inspect hydraulic hose and fittings. If OK, do Step
2.
b. Replace hydraulic lines or fittings. (Refer to page
16-26.)
Step 2.
Defective main hydraulic relief valve.
a. Check relief valve adjustment. (Refer to page 16-54.)
If OK, do Step 3.
b. Contact Direct Support Maintenance to replace relief
valve.
Step 3.
Defective hoist.
a. Contact Direct Support Maintenance.
3-42