TM 5-3810-307-24-1-1
WARNING SUMMARY
Page
2-9-6
WARNING
Minor concentrations of acetic acid vapor may be produced during
application. Adequate ventilation should be provided when silicone RTV
is applied in confined areas.
WARNING
2-9-6
Eye contact with these silicone RTV materials may cause irritation. If eye
contact takes place, flush the eyes with water for 15 minutes and have the
eyes examined by a doctor.
WARNING
2-9-11
Failure to maintain proper torque of the turntable bearing attaching bolts
will result in damage to the crane and possible injury to personnel.
2-9-11
WARNING
It is mandatory that bearing attaching bolts be inspected for lack of torque
and retorqued, as required, after the first 300 hours of machine operation.
The bolts may loosen in service due to vibration, shock-loads, and
temperature changes, therefore, periodic inspection should be
accomplished every 500 hours thereafter, ensuring the bolts are properly
torqued.
2-9-3