TM 5-3810-307-24-1
Section IV. REMARKS
REMARKS
CODE
REMARKS
A
Repair of lights limited to bulb replacement.
B
Harness repair at Organizational level limited to connector replacement.
C
Repair of all holding and check valves limited to replacement of seal kits.
D
Cab repair at the Organizational level includes replacing window glass, door assembly,
locks, brackets, etc.
E
Service at Organizational level is for record keeping purposes only.
F
Service at Organizational level is limited to replacement of governor filter.
G
Service at Crew level limited to servicing fuel tank.
H
Service at Crew level limited to servicing hydraulic reservoir.
I
Limited Field Repair authorized (Seals, Gaskets, Bearings, Plugs & Cylinder Head).
J
Radiator repair limited to replacement of pressure cap, drain valve & soldering minor
leaks.
K
L
Starter repair limited to bearings, brushes and solenoid replacement.
M
Repair limited to replacement parts on the brake shoes.
N
Repair is limited to replacement of parts on the brake chambers.
O
Repair limited to light body work and replacement of down parts..
P
Differential repair at the Field level is limited to input / output seal replacement.
Q
Electric swivel repair at the field level is limited to cleaning or replacing the brushes /
contacts.
R
Espar Hydronic engine coolant heater and Arctic Fox Hydra Liner hydraulic tank
heaters installed on some cranes. If installed, procure spare parts in accordance with
TM 5-3810-307-24P, Appendix A. If field installation is required, order the installation
kits (two) identified in Appendix A and install the kits in accordance with TM 5-3810-
307-24-1-2, Appendix J.
A-21/(A-22 Blank) C-1