TM 10-3950-672-10
5-3.
OPERATING PROCEDURES.
5-3.1
Normal Engine Starting.
WARNING
Before starting the engine, ensure the parking brake is applied.
CAUTION
Never crank the engine for more than 30 seconds during an attempted start. If the engine
fails to start after 30 seconds, allow the starter motor to cool for approximately two minutes
before attempting another start.
NOTE
The engine will not crank unless the 1-2-D-N-R lever (11, Figure 5-1) is in the neutral (N)
position.
(a) Turn the IGNITION switch (28) to START and release immediately when the engine starts.
(b) Check engine instruments for proper indications.
CAUTION
If oil pressure and/or temperature indicator(s) do not display proper readings, shut down the
engine and correct the malfunction before resuming operation.
(c) Allow the engine and hydraulic oil to warm up at least five minutes before applying a load.
NOTE
Gauge readings are given as a guide only. Readings may be slightly higher or lower
depending on the individual engine condition. If in doubt, refer to the applicable engine
service or operation manual.
5-23