TM 5-3810-295-34
Figure 14-24. Run-out flywheel housing bore.
(8) Check readings at B and B1. If total run-out
exceeds 0.010 inch, use a pinch bar to move housing
one-half of the total indicator reading to center housing
horizontally.
(9) Check readings at A and A1. If total run-out
exceeds 0.010 inch, remove dowel and pry housing
either up or down one-half of the total reading to
center vertically.
(10) Recheck, until both the horizontal (B and
B1) and vertical (A and A1) are within limits without ad-
justment to housing.
(11) Tighten screws (1, 2, 3 and 4, fig. 14-21)
alternately to 30-35 ft-lb (41-48 N m) torque.
Torquing sequence is shown in figure 14-25.
Figure 14-25. Flywheel housing torque sequence.
14-25