6. REACHING MAXIMUM ALLOWABLE LOAD MOMENT
The line between the red and yellow zone at the load-moment meter represents 100 % of allowable load moment.
If the crane reaches this limit, the Krueger load moment indicator will indicate this condition by:
- LOAD MOMENT ALARM LIGHT - ON
- LOAD MOMENT INDICATOR NEEDLE ON LINE BETWEEN RED AND YELLOW AREA
- HORN WILL SOUND
The load moment must now be reduced by retracting or elevating boom until load moment indicator needle is in operating
range.
Alarm light should go out indicating system is again ready for operating.