VOLTS
MIN. AMPS
MAX. AMPS
MIN RPM
MAX RPM
20
70
110
5500
9000
Table 10D-1. Starter Motor No Load Specifications
I n t e r p r e t i n g Results of Tests
4. Failure to operate with no current
draw indicates:
1. Rated current draw and no load speed
indicates normal condition of the crank
motor.
A. Open field circuit.
This can be
checked after disassembly by inspect-
2. Low free speed and high current draw
ing internal connections and tracing
indicates:
circuit with a test lamp.
A. T o o m u c h f r i c t i o n - t i g h t , d i r t y , o r
B. Open a r m a t u r e coils.
Inspect the
commutator for badly burned bars af-
or loose pole shoes allowing the arma-
ter disassembly.
ture to drag.
C. Broken
brush springs, worn
B. Shorted armature. This can be fur-
brushes, high insulation between the
ther checked on a growler after dis-
commutator bars or other causes
assembly.
which would prevent good contact be-
tween the brushes and commutator.
C. Grounded armature or fields. Check
further after disassembly.
5. Low no load speed and low current
3. Failure to operate with high current
due to poor connections, defective leads,
draw indicates:
commutator
and
causes
listed
dirty
above.
A. A direct ground in the terminal or
fields .
6. High free speed and high current
draw indicates shorted fields. If shorted
fields are suspected, replace the field
been determined by turning the arma-
coil assembly and check for improved
performance.
ture by hand).
Electrical
Components