TM 5-3810-306-10
TABLE 3-1. OPERATOR TROUBLESHOOTINC (CONTD)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b. Contact Organizational Maintenance to remove intake hood and air filter element. Replace air
filter element and clean intake hood.
Step 3.
Fuel contaminated.
a. Check fuel sediment bowl for contamination. If fuel ok, do step 4.
Step 4.
Contact Organizational Maintenance.
3.
ENGINE CRANKS, BUT WILL NOT START - NO SMOKE FROM EXHAUST
Step 1.
No fuel in tank.
a. Check fuel level in tank. If ok, do step 2.
b. Service fuel tank.
Step 2.
Fuel-water separator plugged with water.
a. Drain fuel-water separator.
4.
ENGINE STARTS BUT WILL NOT KEEP RUNNING
Step 1.
Engine starting with hydraulic pump engaged.
a. Check position of hydraulic pump disconnect lever. If pump disengaged, do step 2.
b. Disengage hydraulic pump.
3-4