TM 5-3810-306-10TABLE 3-1. OPERATOR TROUBLESHOOTINC (CONTD)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONb. Contact Organizational Maintenance to remove intake hood and air filter element. Replace air filter element and clean intake hood.Step 3.Fuel contaminated.a. Check fuel sediment bowl for contamination. If fuel ok, do step 4.Step 4.Contact Organizational Maintenance.3.ENGINECRANKS,BUTWILLNOTSTART-NOSMOKEFROMEXHAUSTStep 1.No fuel in tank.a. Check fuel level in tank. If ok, do step 2.b. Service fuel tank.Step 2.Fuel-water separator plugged with water.a. Drain fuel-water separator.4.ENGINESTARTSBUTWILLNOTKEEPRUNNINGStep 1.Engine starting with hydraulic pump engaged.a. Check position of hydraulic pump disconnect lever. If pump disengaged, do step 2.b. Disengage hydraulic pump.3-4