TM 5-3810-306-20TABLE 3-1. ORGANIZATIONAL TOUBLESHOOTING (CONT)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION74. NOCABHEATERIGNITIONVOLTAGEStep 1.Corroded or loose electrical connections at heatercontrol.a. Check wiring to heater. Clean and/or tightenelectrical connections.Step 2.Electrical connections (wiring) mixed.a. Check wiring connections. If installed properly, doStep 3.b. Remove and properly install electrical connections.Step 3.Switch failure.a. Remove and test ON/OFF switch. If OK, do Step 4.(Refer to page 8-34.)b. Replace ON/OFF switch.Step 4.Defective heater.a. Contact Direct Support Maintenance.75. CABHEATERMOTORDOESNOTSTARTStep 1.Corroded or loose electrical connections to heatercontrol.a. Check wiring to heater. Clean and/or tightenelectrical connections.Step 2.Heater switch failure.a. Remove and test ON/OFF switch. If OK, do Step 3.b. Replace ON/OFF switch. (Refer to page 8-34.)Step 3.Defective heater.a. Contact Direct Support Maintenance.3-53
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business