TM 5-3810-306-20
TABLE 2-1. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INTERVAL
ITEM TO BE INSPECTED
ITEM NO
PROCEDURE: CHECK FOR AND HAVE REPAIRED, FILLED, OR ADJUSTED AS NEEDED
M
Q
S
A
B
H
PERFORM ALL OPERATOR PMCS FIRST
COOLING SYSTEM (CONTINUED)
6
1000
Check condition of radiator cap using pressure tester. Test pressure
.
is 10 psi.
ELECTRICAL SYSTEM
WARNING
Do note smoke or allow flame or spark in the vicinity while checking or
filling the batteries. The batteries generate hydrogen - a highly
explosive gas. Wear safety goggles when adding distilled water.
CAUTION
In cold operation, charge batteries immediately after water has been
added to prevent freezing and damage to batteries; run crane engine for
one hour at 1500 rpms.
7
Check battery cables and connections for corrosion. Clean batteries and
connections. Replace cables If necessary (Refer to page 8-107.)
8
Check battery box for damage and corrosion. Replace if necessary
(Refer to page 8-101.)
9
250
Perform STE/ICE System Self-Diagnostic Test. (Refer to page 3-59.)
10
250
Perform STE/ICE individual battery test. (Refer to page 3-59.)
M - MONTHLY
S - SEMI-ANNUALLY
B - BIENNIALLY
Q - QUARTERLY
A - ANNUALLY
H - HOURS
2-10