TM 5-3810-306-20TABLE 2-1. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICESINTERVAL ITEM TO BE INSPECTEDITEM NO PROCEDURE: CHECK FOR AND HAVE REPAIRED, FILLED, OR ADJUSTED AS NEEDEDM Q S A B H PERFORM ALL OPERATOR PMCS FIRSTCOOLING SYSTEM (CONTINUED)6 • 1000 Check condition of radiator cap using pressure tester. Test pressure. is 10 psi.ELECTRICAL SYSTEMWARNINGDo note smoke or allow flame or spark in the vicinity while checking orfilling the batteries. The batteries generate hydrogen - a highlyexplosive gas. Wear safety goggles when adding distilled water.CAUTIONIn cold operation, charge batteries immediately after water has beenadded to prevent freezing and damage to batteries; run crane engine forone hour at 1500 rpms.7 Check battery cables and connections for corrosion. Clean batteries andconnections. Replace cables If necessary (Refer to page 8-107.)8 Check battery box for damage and corrosion. Replace if necessary(Refer to page 8-101.)9 • 250 Perform STE/ICE System Self-Diagnostic Test. (Refer to page 3-59.)10 • 250 Perform STE/ICE individual battery test. (Refer to page 3-59.)M - MONTHLY S - SEMI-ANNUALLY B - BIENNIALLYQ - QUARTERLY A - ANNUALLY H - HOURS2-10