TM 5-3810-306-20TABLE 2-1. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICESINTERVAL ITEM TO BE INSPECTEDITEM NO PROCEDURE: CHECK FOR AND HAVE REPAIRED, FILLED, OR ADJUSTED AS NEEDEDM Q S A B H PERFORM ALL OPERATOR PMCS FIRSTENGINE LUBRICATING SYSTEM• NOTESome intervals are expressed in time and operating hours. Perform thePMCS procedure at whichever interval occurs first.1 1000 Adjust rocker lever, rocker lever shaft, and valves. (Refer to page 4-2.)-IFUEL SYSTEM2 • Clean air cleaner filter element if dirty. Replace if damaged.3 500 Replace fuel water separator filter. (Refer to page 5-15.)4 500 Replace in-line fuel filter (Refer to page 5-13.)COOLING SYSTEMWARNINGThe cooling system is pressurized. Personal injury may result whenremoving the radiator cap after operating temperature is reached. Do notremove radiator cap when radiator is hot to touch.5 • Drain radiator old coolant, backflush with fresh water and refill withanti-freeze coolant mixture (50/50 mixture of MIL-A-46153 and water).Replace coolant filter. (Refer to page)M - MONTHLY S - SEMI-ANNUALLY B - BIENNIALLYQ - QUARTERLY A - ANNUALLY H - HOURS2-9