TM 5-3810-307-10
8 ERROR CODES - continued
ERROR
ERROR
CAUSE
ACTION
CODE
a.) Check cable. Replace if
a.) Cable from central unit to
Upper limiting value for
E21
the length/angle sensor is
the measuring channel
b.) Replace and reset length
defective or loose.
"length" exceeded
potentiometer. See
b.) Length potentiometer is
Procedure 5.
defective.
c.) Replace main board and
c.) Electronic component in
reset pressure channels. See
the measuring channel is
Drawing 3 & Procedures 3
defective on main board.
and 4.
a.) Check cable as well as
a.) Cable from central unit to
Upper limiting value for
E22
plug. Replace if necessary.
the pressure transducer is
the measuring channel
See Section 7.
defective, loose or water in
"pressure piston side"
b.) Replace pressure
the plug.
exceeded
transducer and reset pressure
b.) Pressure transducer on
channels. See Section 7.
piston side is defective,
c.) Replace main board and
c.) Electronic component in
reset pressure channels. See
the measuring channel is
Drawing 3 & Procedures 3
defective on main board.
and 4.
a.) Check cable and
a.) Cable lead in from the
Upper limit value for the
E23
connectors as well and
central unit to pressure
measuring channel
replace, if necessary. See
transducer is defective, not
"pressure transducer rod
Section 7.
connected or water in the
side" exceeded
b.) Replace pressure
connectors.
transducer.
b.) Pressure transducer on
c.) Replace main board and
road side is defective,
reset pressure channels. See
c.) Electronic component in
Drawing 3 & Procedures 3
the measuring channel is
and 4.
defective.
a.) Check cable as well as
a.) Cable leading from the
Upper limit value for the
E25
connectors and replace, if
central unit to the
measuring channel
length/angle sensor is
"angle main boom"
b.) Replace angle sensor and
defective, loose or water in
exceeded
reset adjustment. See
the connectors.
Section No. 6 & Procedure 5.
b.) Angle sensor is defective
c.) Replace main board and
c.) Electronic component in
reset pressure channels. See
the measuring channel is
Drawing 3 & Procedures 3
defective.
and 4.
Change 1 G-37