TM 5-3810-307-10
PROBLEM: Error code displayed. Lever lockout activated. Warning lights on.
ERROR
ERROR
CAUSE
ACTION
CODE
Lower boom back to a radius
Fallen below the minimum
E01
Minimum radius or
or angle given in the load
radius or above the angle
maximum angle range
chart.
given in the load chart due to
exceeded
raising the boom too far.
Raise boom back to a radius
The maximum radius or
E02
Maximum radius or
or angle given in the load
minimum angle given in the
minimum angle range
load chart was exceeded due chart.
exceeded
to lowering the boom too far.
Set operating mode switch
E04
Operating mode not
Operating mode switch in the
correctly to the code assigned
available
console set incorrectly.
to the operating mode of the
Operating mode is not
crane.
permissible with actual crane
configuration.
Boom has been extended too Retract or extend boom to
E05
Length range not
far or not far enough. Length correct length given in the
permitted
sensor adjustment changed; load chart. See Section 6.
i.e. length sensor cable slid
off the cable drum.
Replace relay.
E07
No acknowledgment
defective or not being
signal from overload
selected.
Anti-Two Block switch relay is Replace relay.
E08
No acknowledgment
defective or not being
signal from Anti-Two
selected.
Block switch relay (K2)
a.) Check cable and connector
a.) Cable between length
E11
Fallen below limit for the
as well and replace, if
sensor and central unit is
measuring channel
defective, not connected or
"length"
b.) Replace and reset length
water in the connectors.
sensor potentiometer. See
b.) Length sensor
potentiometer is defective.
c.) Replace main board and
c.) Electronic board in the
reset pressure channels. See
measuring channel is
Drawing 3 & Procedures 3
defective.
and 4.