TM 5-3810-307-10
e. Position Top Lead Section on ground facing
single tower structure.
the crane boom and next to Adapter Plates.
f. Place Right Adapter Plate on clean Boom
Position required number of Lower Lead
Point Crane Pin and install end can and two
Sections on ground and in line with the Top
bolts. Tighten bolts.
Lead Section.
g. Place Left Adapter Plate on clean Boom
Point Crane Pin and install Pin End Can and
(4). ASSEMBLING COMPONENTS.
a. With crane located in line with leads
as shown in Figure 8. ensure rear superstruc-
ture is rotated so that boom is facing the rear of
the crane.
h. Remove sheave cable guide pin, as shown in
Figure 10. Right and Left Crane Adapter Plates
tower is hoisted into upright position.
b. Tilt crane front-to-rear and level left-to-right
by extending outriggers. Raise front of crane
and lower rear of crane. When correct, crane
will be left to right level and front to rear tilted
and fully supported on its outriggers.
c. Raise and/or lower boom so that adapter
plates attachment shafts. on the end of the
boom. are at working level.
NOTE
Adapter Plates are not interchangeable. there
is a left Adapter Plate and a Right Adapter
Plate. The RIGHT side Adapter Plate has a
step-down hole size to interface the pivot pin
shaft, that has a step down shaft size. The
LEFT side Adapter Plate has a single size
hole. Left and right side plates are orientated
from the driver's seat of the front cab.
d. Remove two bolts from each side holding
boom point crane pin end caps and remove end
caps.
e. With supplied hardware, assembly and bolt
Lead Tower into Upright position.
the Top Lead Section and the required number
of Lower Lead Sections together to form a
L-5 C-1