TM 5-3810-307-24-1-1
Lube Amount -
17.3 quarts (16.4 L)
Application -
Fill to full mark on dipstick.
Complete the following steps after each engine oil change to make sure the engine receives the correct oil
flow through the lubricating oil system.
Disconnect electrical wire from fuel pump solenoid valve.
Rotate the crankshaft, using the starter motor, until oil pressure appears on the gauge, or warning
light goes out.
Connect electrical wire to fuel pump solenoid valve.
Start engine, refer to Section 5, TM 5-3810-307-10.
Refer to Fuel System Bleeding, Section 5, for instructions to vent the fuel system.
25. Transmission and Torque Converter.
Lube Type -
OE/HDO-10 [-10F to +120F (-23C to 49C)]
OEA [-50F to +10F (-46C to -12C)]
OE/HDO-30 [100F to +120F (38C to 49C)]
NOTE
When checking oil level, the oil temperature must be stabilized at 180 degrees to 200
degrees F (82.2 degrees to 93.3 degrees C) to properly check the oil level. Do not at-tempt
an oil level check with cold oil. To bring the oil temperature to this range, it is necessary to
either work the crane or stall the converter. Converter stall should be accomplished by
engaging the shift levers in forward and high range with the brakes applied and then
accelerating the engine to half or three-quarter throttle. Hold the stall until the desired
converter temperature is reached and stabilized.
CAUTION
Full throttle stall speeds for an excessive length of time will over-heat the converter and
cause serious damage.
(Text Deleted)
Lube Interval -
Check level daily. Drain and refill every 1000 hours. Change oil filter element when
changing oil.
NOTE
If oil filter element is being changed in temperatures at or below 30F (-1C) or oil is being
changed to arctic grade (OEA), use filter element installation procedures annotated on
cartridge plus turn.
Lube Amount -
28 quarts (26.5 L)
Application -
Fill to full mark on dipstick.
25. Drive Line Slip Joints and U-joints.
Lube Type -
GAA
Lube Interval -
1000 miles (1600 km)
Lube Amount -
Until grease extrudes
Application -
6 fittings
1-4-6 C-1