Starting Procedure Matrix
Idle Throttle
Full Throttle
Automotive/Industrial
All pumps above 16C [60F]......................................... X (after 5 sec, see Note)
All pumps below 16C [60F] ....................................................................................................... X Note
NOTE
Full throttle is applied after engaging starter.
Disengage the driven unit, or if equipped, put the transmission in neutral.
Position the fuel shut-off, electrical switch or mechanism control to the RUN position.