TM 5-3810-307-24-2-2
Clean all parts in solvent and use compressed air to
dry.
Inspect the pump housing and gerotor drive for
damage and excessive wear.
NOTE
Be sure the gerotor planetary is
installed in the original position.
Install the gerotor planetary.
Measure the tip clearance.
Tip Clearance
mm
in
0.1778
MAX
[0.007]
7-14