TM 10-3950-672-24-2
Remove the oil drain plug and allow the mineral oil to
drain from the engine.
Remove the lubricating oil filter. Install a new filter
according to the manufacturer's specifications.
Pressure fill the engine with 15W40 lubricating oil
through the 1.8 inch pipe tap on the side of the oil filter
housing directly below the turbocharger oil supply
connection. Use 207 kPa (30 psi) to pressure fill the
system with a minimum of 3.6 L (1 U.S. gal).
Caution: Make sure the engine does not start when
you crank the engine by disconnecting the fuel
solenoid or positioning the shut down lever in the
stop position.
Use the starter to crank the engine for a maximum of 30
seconds, with two minute intervals, until oil pressure
registers on the lubricating oil gauge.
5-345