TM 10-1670-298-20&PFigure 2-20. Fabrication and Installation Details of the Safety Clip Retaining Strapsf. Position the folded end on top of the quick release strap with the folded end edge located 1 7/1 6-inches (4.920cm) from the end of the quick release strap webbing where the lug is attached.NOTEA replacement, fabricated safety clip retaining strap may be secured to any serviceablequick release strap.g. Stitch the folded end of the safety dip retaining strap to the quick release strap with a box stitch formation usingthe specifics In Table 2-3.h. Insert safety dip into the 3/8-inch (O 956 cm) loop of the safety clip retaining strap.REPLACEA defective quick release strap shall be replaced with a serviceable item from stock.2-42