(3)Place new ground strap in position and secure to
engine with IET washer and capscrew.
(4)Connect ground strap to generator and secure
with IET washer and capscrew.
c. Voltage Regulator.
secures regulator and two mounts, and remove
regulator.
(2)Place new regulator in position with two mounts
and secure with four screws and nuts.
d. Heaters.
(1)Remove screw and IET washer that secures
(2)Remove screw and IET washer that secures
ground strap to heater base, then remove ground strap.
(3)Place new ground strap in position and secure to
heater base with IET washer and screw.
(4)Position ground strap on heater and secure with
IET washer and screw.
3-55. Testing of Radio Interference Suppression
Components
Test any capacitors for leaks and shorts on a capacitor
tester; replace defective capacitors. If test equipment is
replacing each capacitor in turn until the cause of
interference is located and eliminated.
Figure 3-41. Radio interference suppression
components
3-51