TM 5-3810-207-20/TO 36C23-3-37-12
Figure 182. Quick release valve, removal and installation.
300. Relay Valve
a.
Removal. Remove the relay valve as
instructed on figure 183.
b.
Cleaning and Inspection.
(1)
Clean the relay valve with an approved
cleaning solvent.
(2)
Inspect
the
relay
valve
for
proper
operation. Replace a defective relay
valve as necessary.
(3)
Inspect all fittings and mounting hardware
for stripped or damaged threads. Replace
all parts as necessary.
c.
Installation. Install the relay valve as
illustrated on figure 183.
236