TM 5-3810-207-20/TO 36C23-3-37-12Figure 2. Crane-shovel and tiedown, removal.(2)When the crane-shovel is received withnew. dry-charge batteries and electrolyteis packed separately, perform thefollowing services:(a)Remove the battery box cover andfiller caps (TM 5-4810-207-10).(b)Pour electrolyte into each batterycell to a depth of 3/8 inch above theseparators.(c)Install the fillercaps and battery boxcover (TM 5-3810-207-10).Caution:Exercise care when filling thebatteries with electrolyte to preventsplashing or spilling the acid onclothing and body.Note.The carrier and crane batteries areserviced in the sane manner.(3)When the crane-shovel is received withwet batteries, service the batteries (TM 5-3810-207-10). For information on batterytest and maintenance, refer to TM 9-6140-200-15.(4)When the crane-shovel is received in coldweather, fill the crane and carrier enginecooling systems with antifreeze solution toprotect the system to the lowest expectedtemperature. Refer to table I and TBENG-60 as a guide.12