6.
Allow the engine to idle at least five minutes giving the hydraulic oil time to warm up.
SHUTDOWN PROCEDURE.
1.
Operate the engine at fast idle for approximately five minutes to avoid high internal heat rise and
2.
Position the ignition switch to off.
3.
Depress the engine stop button.
EMERGENCY SHUTDOWN.
When the engine will not stop using the regular SHUTDOWN PROCEDURE, use the emergency
shutdown knob. This knob is located in the carrier cab. After the engine has stopped, the shutoff valve
must be reset before the engine can be restarted (see the CARRIER OPERATORS HANDBOOK).
CAUTION
CORRECT THE MALFUNCTION THAT REQUIRED THE EMERGENCY SHUTDOWN BEFORE
RESUMING OPERATIONS.
41