INJECTOR TIMING GAGE CHART ("C" Injectors)
Fig. 3 - Positioning No. I Injector Rack Control Lever

Maintenance Manual For Crane, Truck Mounted Hydraulic 25 Ton (CCE) - Vol 3 Page Navigation
  373    374    375    376    377  378  379    380    381    382    383  
img
TM 5-3810-300-24&P-3
14.3
LIMITING SPEED MECHANICAL GOVERNOR AND INJECTOR RACK CONTROL ADJUSTMENT
Adjust the limiting speed mechanical governor and the
injector rack control levers, after adjusting the exhaust
valves and timing the fuel injectors.
NOTE: Loosen the lever for the fuel
modulator, the load limiting device or
disconnect the air cylinder link, if the
engine
is
so
equipped,
before
proceeding
with
the
governor
adjustment.
Fig. 2 Adjusting Gap
Adjust Governor Gap
With the engine at operating temperature, adjust
the governor gap as follows: