TM 5-3810-302-10
EMERGENCY HAND PUMP OPERATION
Per procurement spec, provisions are included on the SCAMP to return the
crane to travel mode in the event of hydraulic power loss. The following is the
procedure:
Remove the access cover on front outrigger box. Locate the 1 /4" hand
1.
pump supply hose entering compartment on right side (facing front of crane).
This hose has a female quick disconnect half on its end and lies loose across
the compartment, having approximately 18 inches of slack.
Remove the hand pump, pump handle, and hose from their stowed
2.
positions in the right-hand tool compartment. The hose has a female quick
disconnect half on one end and a male quick disconnect half on the other.
The pump has one each male and female quick disconnect on its supply and
pressure ports.
Using the bracket provided on the pump, clip the pump onto the lower
3.
edge of the access cut-out in the front outrigger box. Install the pump handle
and attach the male end of the hose to the female outlet on the pump.
Remove the pump supply hose and plug it into the male quick
4.
disconnect half on the pump. Uncoil and extend the hand pump pressure
hose,
Connect the hand pump pressure hose (with male quick disconnect
5.
half) to the female end of the hoist brake line quick disconnect installed on