T M 5 - 3 8 1 0 - 3 0 5 - 1
Never allow electrically con-
nected electrode holders to
contact metal components of a
work platform. Electrode holder
contact can cause burning and/or
melting of work platform suspen-
sion which could allow the work
platform to fall. Failure to
follow this procedure could cause
DEATH or serious injury,
l If a welding operation is to be
performed, make certain electrode
holders do not contact metal
components of the work platform.
l When the work platform is suspended
from a load line, a stabilizing tag line
must be attached to the work platform
and controlled to minimize any swaying
motion.
1-47 (1-48 blank)