TM5-3810-305-10
Never lift and swing a load
directly over operators compart-
ment or over ground personnel in
the work area. Failure to follow
this procedure could cause
DEATH or serious injury.
CAUTION
ALWAYS START AND STOP
SWINGS GRADUALLY.
Stopping swing too abruptly
cause load to oscillate and
impose side loads on boom.
will cause damage to boom.
will
This
When ready, try for a smooth, controlled, safe
swing. The swing should be SLOW. Start
SLOWLY and allow load to buildup just enough
momentum to carry it through to the point where
it is to be lowered. Begin slowing swing in
advance of point where load is to be lowered.
Slow swing GRADUALLY, enabling it to
coast to a stop over desired spot.
If properly executed, load will hang motionless
when swing is terminated. If load is oscillating,
swing was made too rapidly and/or stopped too
abruptly.
5
. .
Extend boom to desired length (refer to the
Capacity Chart). EXTEND boom by pushing
extend/retract lever forward and RETRACT
by pulling lever back.
CAUTION
Never pull to the side with a
crane boom. Crane booms are
not designed for excessive side
pull and may collapse if sub-
jected to excessive side loading.
6. Lower hook block to load and fasten hook.
Make sure hook is properly engaged in slings
or lifting device employed to make the lift.
Be certain hook latch is not supporting any of
the load (refer to warning decal on hook
block).
Hoisting or lowering load with winch is con-
trolled by winch lever. To LOWER load, push
lever forward. To RAISE load, pull lever back.
Improved control is obtained by operating engine
at low speed while metering control.. Always
actuate and release this lever slowly to minimize
dynamic effects on load and to prevent bird
caging of cable on winch drum.
l
l
Never operate equipment with
personnel on the hook or a
load. Failure to follow this
procedure could cause DEATH
or serious injury.
Crane operators must always
be prepared to take emergency
action while a load is
suspended in the air. Never
leave the operators
compartment with a load
suspended. Failure to follow
this procedure could cause
DEATH or serious injury.
7. Lift load to desired height. Do not lift higher
than necessary.
The LRT 110 Crane is equipped with an anti-two
block system. If hook or block is raised too close
to boom head, a warning light appears on panel.
If horn switch is activated, an audible warning
will sound. This vehicle is also equipped with
control disconnects to prevent winch from
raising load and boom from extending or lower-
4-24