TROUBLESHOOTING PROCEDURES - PUMPS
TROUBLESHOOTING PROCEDURES - PUMPS - Continued

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  69    70    71    72    73  74  75    76    77    78    79  
img
. . .
TM 5-3810-305-23
0012
MALFUNCTION
Shaft or Parts Broken Inside Hydraulic Pump(s).
CORRECTIVE ACTION
Replace hydraulic pump(s) (WP 0134).
MALFUNCTION
Contamination in Pump(s).
CORRECTIVE ACTION
1.
Locate origin of contamination and correct.
2.
Drain and flush entire hydraulic system.
3.
Replace hydraulic pump(s) (WP 0134).
SYMPTOM
LOW OR NO PRESSURE IN SYSTEM
MALFUNCTION
Engine Rpm Too Low.
CORRECTIVE ACTION
Adjust low idle rpm.
MALFUNCTION
Relief Valve Set Too Low.
CORRECTIVE ACTION
Adjust relief valve setting (WP 0147).
MALFUNCTION
Hydraulic Oil Leaking.
CORRECTIVE ACTION
1.
Check hydraulic system for leaks.
2.
Repair leaks.