TROUBLESHOOTING PROCEDURES - PUMPS - Continued
TROUBLESHOOTING PROCEDURES - RELIEF VALVES

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
img
.
TM 5-3810-305-23
0012
MALFUNCTION
Solid Matter Being Wedged in Hydraulic Pump(s).
CORRECTIVE ACTION
1.
Locate origin of contamination and correct.
2.
Drain and flush entire hydraulic system.
3.
Replace hydraulic pump(s) (WP 0134).
END OF WORK PACKAGE