TM 5-3810-306-20c. Wipe adapters clean of sealant with rag.d. Pull two hoses (11 and 12) from water outlet andwater inlet connectors.3.INSPECT PARTS FOR DAMAGE. REPLACE ASREQUIRED.INSTALLATION:1.ASSEMBLE TOP AND BOTTOM RADIATORHOSES AND TUBES.a. Connect four hoses and two tubes.b. Loosely install eight clamps (4) around ends oftop and bottom radiator hoses.c. Loosely install capscrew (5), new lockwasher (6),flatwasher (7), and tube clamp (8) to bottom tube(13).2.JOIN HOSES (11 AND 12) TO WATER INLET ANDOUTLET CONNECTORS. TIGHTEN CLAMPS (4).CAUTIONDo not apply sealant to inside ofhose. This results in clogged coolantpassages and premature enginefailure.3.JOIN HOSES (9 AND 10) TO RADIATORADAPTERS.a. Apply a moderate amount of permatex No. 2 tomate ends of radiator adapters.b. Push hoses (9 and 10) on adapters. Wipeexcess sealant with rag.c. Tighten two hose clamps (4) on radiatoradapters.7-7