TM 5-3810-306-20
Section III.
HYDRAULIC RESERVOIR
MAINTENANCE
EMERGENCY HAND PUMP INSTALLATION
TOOLS:
General mechanic’s tool kit: automotive (
5180-00-177-7033
)
SUPPLIES:
Lockwashers (Item 15, Appendix C)
Preformed packing (Item 12, Appendix C)
Hydraulic oil (Item 6, Appendix C)
Loctite #545 (Item 13, Appendix C)
EQUIPMENT CONDITIONS: Disconnect ground cable at shunt. (Refer to page 8-109.)
REMOVAL:
1.
REMOVE EMERGENCY HAND PUMP (2).
a. Tag and disconnect one hydraulic hose (1) to
emergency hand pump (2). Discard preformed
packing (8).
b. Remove four capscrews (4),
lockwashers
(5)
and flatwashers (6) securing hand pump (2) on
mounting bracket (7). Discard
lockwashers
(5).
c. Remove emergency hand pump (2).
d. Place pump in vice and remove fittings (3) and
retain for reassembly.
INSTALLATION:
1.
INSTALL EMERGENCY HAND PUMP (2).
NOTE
Coat threads on fittings and hoses
with Loctite 545. Coat preformed
packing with clean hydraulic oil.
a. Install fittings (3) on hand pump (2).
16-46