TM 5-3810-307-10
a.
Place BATTERY DISCONNECT switch of disabled vehicle in the off
position.
b.
Connect another vehicle having a compatible NATO slave intervehicular
cable and a 24 VDC electrical system to disabled vehicle's NATO slave
receptacle located on battery box.
c.
Place BATTERY DISCONNECT switch of disabled vehicle in the on position
d.
Start engine of source vehicle and then disabled vehicle's engine. When
engine is running smoothly, disconnect the NATO slave intervehicular cable.
Emergency Shutdown. Should moving the IGNITION Switch to the 0 (off) position
fail to shut off the engine, perform the following steps:
CAUTION
Do not use the BATTERY DISCONNECT switch as
an emergency stop switch. Moving the BATTERY
DISCONNECT switch to off will not shut down the
engine and could result in damage to the alternator.
a.
Ensure IGNITION Switch is positioned to 0 (off) and PARK BRAKE Control
is pulled out (parking brake applied).
b.
Open and secure left side engine access door.
c.
Rotate fuel shutoff lever (Figure 5-9) clockwise to the stop and hold until
engine stops running.
5-103