TM 5-3810-307-10
20. Swing Brake.
Lube Type -
OE/HDO-10
Lube Interval -
Check every 1000 hours. Drain and refill every 2000 hours.
Lube Amount -
0.5 pint (0.2L)
Application -
Drain oil from lower bleed plug. Fill through upper bleed plug until level with
bottom of upper plug.
21. Not Used
22. Upper Lift Cylinder Pivot.
Lube Type -
GAA
Lube Interval -
500 hours
Lube Amount -
Until grease extrudes
Application -
1 fitting
23. Lower Lift Cylinder Pivot.
Lube Type -
GAA
Lube Interval -
500 hours
Lube Amount -
Until grease extrudes
Application -
1 fitting
24. Not Used
25. Hydraulic Tank.
Lube Type -
OE/HDO-10
Lube Interval -
Check level daily. Drain and refill every 2000 hours. Replace both hydraulic
filters.
Lube Amount -
Capacity 64.4 gallons (243 L)
Application -
Fill through the cap on top of the tank. When tank is drained, clean the magnetic
pipe plug. Replace both the in-tank and steering system hydraulic filters when
changing oil.
26. Not Used
27. Pintle Hook.
Lube Type -
GAA
Lube Interval -
250 hours
Lube Amount -
Until grease extrudes
Application -
3 fittings
28. Air Conditioners.
Lube Type -
HFC
Lube Interval -
Drain and refill annually
Lube Amount -
As required to fully charge system
Full Charge:
Superstructure - 3.50 lbs
Carrier - 2.50 lbs.
Application -
M-6 C-1