TM 5-3810-307-24-1-1
(1)
Snap louvers (86) into control panel (11).
(2)
Install switch assembly (85) on control panel (11) with screws (84) and route electrical wiring and
thermostat sensor lead from switch assembly through bottom of air conditioner frame (83).
(3)
Install plenum gasket (81) and drain hoses (82) on air conditioner frame (83).
(4)
Install straps (80) on air conditioner frame (83) with washers (79) and locknuts (78).
(5)
Install resistor (77) on fan housing (73) with capscrews (76).
(6)
Install fan housings (73 and 74) on motor (75) with lockwashers (72) and nuts (71).
(7)
Position fan wheels (69 and 70) and retainers (68) on shafts of motor (75) and secure retainers by
tightening setscrews.
(8)
Install rings (67) on fan housings (73 and 74) with capscrews (66).
(9)
Install evaporator fan motor (75) with fans on air conditioner frame (83) with bracket (65), washers
(64), and capscrews (63).
(10) Connect electrical connectors for motor (75) and resistor (77). Remove tags.
(11) Position evaporator coil (62) in air conditioner frame (83), and insert thermostat sensor lead into coil
fins near middle of coil.
(12) Install expansion valve (59) on air conditioner frame (83) with capscrews (60) and locknuts (58).
(13) Connect tubes of evaporator coil (62) on expansion valve (59).
(14) Position cover (61) on air conditioner frame (83), pull straps (80) over cover and hook straps at rear
of frame to secure cover.
(15) Install condenser coil (57) on air conditioner frame (83) with washers (56) and capscrews (54 and
55).
(16) Screw switch (53) into drier (52), install drier (52) on air conditioner frame (83) with clamp (51),
connect electrical connector for switch (53), and remove tag.
(17) Install tube (50) on drier (52) and expansion valve (59). Remove tag.
(18) Install tube (49) on drier (52) and condenser coil (57). Remove tag.
(19) Install relay (48) on air conditioner frame (83) with lockwasher (47) and nut (46). Connect electrical
connector for relay (48) and remove tag.
(20) Position fan (45) and retainer (44) on shaft of condenser fan motor (43), and secure retainer by
tightening setscrew.
(21) Install condenser fan motor (43) on air conditioner frame (83) with clamp (42).
(22) Connect electrical connector for condenser fan motor (43) and remove tag.
NOTE
Install electrical wire ties as necessary to secure electrical wiring.
2-1-42