TM 5-3810-307-24-1-2
R-134a Allowable Container Pressure
F
Psig
F
Psig
F
Psig
F
Psig
F
Psig
The pressures in these
65
69
76
85
87
103
98
125
109
149
English and metric charts
66
70
77
86
88
105
99
127
110
151
refer to recycled and
67
71
78
88
89
107
100
129
111
153
R-134a refrigerant.
68
73
79
90
90
109
101
131
112
156
69
74
80
91
91
111
102
133
113
158
70
76
81
93
92
113
103
135
114
160
71
77
82
95
93
115
104
137
115
163
72
79
83
96
94
117
105
139
116
165
73
80
84
98
95
118
106
142
117
168
118
171
74
82
85
100
96
120
107
144
119
173
75
83
86
102
97
122
108
146
120
176
C
kPa
C
kPa
C
kPa
C
kPa
C
kPa
18
476
25
593
32
752
39
917
46
1124
19
483
26
621
33
765
40
945
47
1158
20
503
27
642
34
793
41
979
48
1179
21
524
28
655
35
814
42
1007
49
1214
22
545
29
676
36
841
43
1027
23
552
30
703
37
876
44
1055
24
572
31
724
38
889
45
1089
Flushing the AC System
Flushing has long been recommended as a means of removing contaminants or other
debris from certain system components. The normal flushing materials, such as
R-11, are now prohibited.
Using compressed air is not a good method of flushing. Air should never be used
in an R-134a system. Closed loop flushing kits are now available, although they may
not remove all foreign material.