THEORY 3. OPERATION OF ANGLE SENSOR
THEORY 4. OPERATION OF PISTON SIDE PRESSURE TRANSDUCER

Maintenance Manual For All-Terrain Crane (ATEC) Diesel Driven, 22 Ton - Vol 1 - Pt2 Page Navigation
  518    519    520    521    522  523  524    525    526    527    528  
img
TM 5-3810-307-24-1-2
PAT DS350 MAIN BOOM ANGLE SIGNAL VOLTAGES
ACTUAL
INPUT SIGNAL AT TERM #4
OUTPUT SIGNAL AT MP8
BOOM
IN CABLE REEL AND TERM
TEST POINT ON MAIN
BOARD IN CU (VOLTS)
ANGLE
X1:9 IN CU (VOLTS)
90
-1.875
0.500
85
-1.944
0.722
80
-2.014
0.944
75
-2.083
1.167
70
-2.153
1.389
65
-2.222
1.611
60
-2.292
1.833
55
-2.361
2.056
50
-2.431
2.278
45
-2.500
2.500
40
-2.569
2.722
35
-2.639
2.944
30
-2.708
3.167
25
-2.778
3.389
20
-2.847
3.611
15
-2.917
3.833
10
-2.986
4.056
5
-3.056
4.278
0
-3.125
4.500
Chart shows typical voltages. These voltages are to be used as reference only, the