TM 5-3810-307-24-1-2
PAT DS350 MAIN BOOM LENGTH SIGNAL VOLTAGES
"OUTPUT" SIGNAL
NO. OF TURNS
NO. OF TURNS
"INPUT" SIGNAL IN
IN VOLTS AT MP6
ON CABLE REEL
ON LENGTH POT.
VOLTS AT TERM.
TEST POINT ON
X1:10 IN CU
MAIN BOARD IN CU
(VOLTS)
(VOLTS)
0
0
-0.50
0.50
3
1
-0.90
0.90
6
2
-1.30
1.30
9
3
-1.70
1.70
12
4
-2.10
2.10
15
5
-2.50
2.50
18
6
-2.90
2.90
21
7
-3.30
3.30
24
8
-3.70
3.70
27
9
-4.10
4.10
30
10
-4.50
4.50
(3 TURNS OF THE CABLE REEL = 1 TURN OF THE LENGTH POT = 0.4V)
Chart shows typical voltages. These voltages are to be used as reference only, the
actual signal may vary slightly. For specific boom length voltages, check voltages at
MP6 or X1:10 and compare with test data in central unit.