Fuel Shutoff Solenoid - Replacement
Injection Pump - Removal

Maintenance Manual For All-Terrain Crane (ATEC) Diesel Driven, 22 Ton - Vol 2 - Pt1 Page Navigation
  133    134    135    136    137  138  139    140    141    142    143  
img
.
TM 5-3810-307-24-2-1
10 mm, 16 mm
Adjust the solenoid linkage as necessary so that the
plunger is magnetically held in with the shutoff lever in
the absolute full run position. Turn the large hex on
the end of the plunger to make adjustments.
Injection Pump - Replacement
Preparatory Steps:
Clean debris.
Remove all fuel lines.
Remove control linkage.
Remove fuel shutoff solenoid.
Remove AFC air line
Remove oil line(s)
A-34 C-1