TM 5-3810-307-24-2-2
Oil - Draining (0-6)
17 mm
Remove the drain plug.
A drain pan with a capacity of 20 litres [5 U.S. gallons] will
be adequate.
Lifting Bracket Removal - Rear (0-7)
18 mm
Remove the rear lifting bracket from the cylinder head.
Drive Belt - Removal (0-8)
Applying excessive force to the tensioner in the opposite
direction of wind-up or after the tensioner has been wound-
up to the positive stop can cause the tensioner arm to
break.
WARNING
Keep hands out of the path of the spring-
loaded tensioner.
1/2 inch or 3/8 inch Square Drive
Release the tension and remove the drive belt.
Service Tip: Loosen the vibration damper/crankshaft and
fan hub pulley capscrews before removing the drive belt.
0-9