Engine Dynamometer Test - Installation of the Engine (14-01) - Continued
Engine Dynamometer Test - Installation of the Engine (14-01) - Continued

Maintenance Manual For All-Terrain Crane (ATEC) Diesel Driven, 22 Ton - Vol 2 - Pt2 Page Navigation
  277    278    279    280    281  282  283    284    285    286    287  
img
TM 5-3810-307-24-2-2
If an external pressure pump is not available, prime the
lubricating system according to the following procedure.
Fill the engine with oil to the high level mark on the
dipstick.
Disconnect the turbocharger lubricating oil supply tube.
Pour 50 cc to 60 cc [2.0 fl. oz. to 3.0 fl. oz.] of clean 15W-40
oil into the turbocharger oil supply hole.
Connect the oil supply tube to the turbocharger.
CAUTION
Mechanical over-tightening can distort the
threads or damage the filter element seal.
Fill the lubricating oil filter with clean 15W-40 oil.
Screw the filter onto the filter head fitting until the gasket
contacts the filter head surface.
Tighten the filter according to the manufacturer's
specifications.
To make sure the lubricating oil pump is providing
adequate oil to the engine, first disconnect any wires
leading to the fuel pump solenoid.
14-11