TM 5-3810-307-24-2-2
Engine Dynamometer Test - Installa-
tion of the Engine (14-01)
Use engine lifting fixture, Part No. ST-125, to install
the engine to the test stand. Align and connect the
dynamometer. Refer to the manufacturer's instructions
for aligning and testing the engine.
NOTE
Make sure the dynamometer capacity is
sufficient to permit testing at 100 percent of
is not enough, the testing procedure must
be modified to match the restrictions of the
dynamometer.
Install the coolant temperature sensor.
107 C [225 F]
Minimum Gauge Capacity:
Connect the coolant supply to the water inlet
connection (1).
Connect the coolant return to the water outlet
connection (2).
Install the drain plugs, close all the water drain cocks,
and make sure all the clamps and fittings are tight.
Connect the vent tube to the vent connection on the
thermostat housing.
Fill the cooling system with coolant to the bottom of the
fill neck in the radiator fill (or expansion) tank.
NOTE
Maximum Fill Rate is 14 Liters/mm [3.5 U.S.
gallons/min]