TM 10-1670-295-23&P
c. Replace. (figure 2-15)
(1)
Cut tether (1) and remove apex fitting (2).
(2)
Cut a 2-foot length of nylon cord.
(3)
Pass cord (tether) through new apex fitting (2) and lifting legs (3).
(4) Tie tether (1) using a square knot and a locking knot.
Figure 2-15. Apex Fitting Replacement.
2-29