TM 10-1670-298-20&P
Figure 2-13. Patching Details for Cover
REPLACE
KEEPER
a. Cut the stitching that secures the keeper to the cover and remove the keeper.
b. Cut a 7 1/2-inch (19.050) length of 1 3/4-inch (4.445 cm) wide Type X cotton webbing from bulk material
(1) Wax the webbing ends.
(2) Position the fabricated strap keeper in the original location on the cover and sew the keeper to the cover with
an hourglass stitch formation using the specifics In Table 2-3.
2-33