73. Generator Regulator
a.
Removal. Remove the generator regulator as
instructed on figure 9.
b.
Cleaning and Inspection.
(1)
Clean the generator regulator with a lint-
free cloth dampened with an approved
cleaning solvent and dry thoroughly.
(2)
Inspect the generator regulator for breaks
and other damage. Replace defective
generator regulator.
c.
Installation. Install the generator regulator as
illustrated on figure 9.
Note.
The
engine
generator
must
be
polarized whenever the leads to the
generator or regulator have been
removed or any adjustments have
been
made
to
the
generator
regulator. Failure to polarize the
generator may cause the regulator
contacts to be damaged by vibration,
heavy arcing, and burning.
Note.
Polarize the generator by disconnec-
ting the field lead at the regulator
and
momentarily
connecting
a
jumper lead between the generator
field terminal and the regulator
battery terminal. Remove the jumper
lead and connect field lead to the
regulator (C, fig. 9).