16. Prepare crane winch for hoisting as follows:
a.
b.
Never disconnect hydraulic lines
or fittings before venting pres-
sure. Turn dipstick 1/4 turn to
safety notch to relieve pressure.
Failure to follow this procedure
could cause SERIOUS INJURY.
Turn dipstick 1/4 turn to safety notch to
relieve pressure.
Disconnect two winch hoses, tagged H-10
and H-11 (Figure 5-13), attached to rotary
manifold with quick disconnect fittings.
These hoses come down from winch on
c.
right side of upperstructure and run in
through hole to rotary manifold. Reach in
and release attaching disconnects on these
hoses.
Remove two coiled extension hoses (Fig-
ure 5-14) from tool box. Their ends are
connected together by quick disconnects,
and are marked with ID tags reading H-10
and H-11. Take them to right side of
vehicle.
Figure 5-14. Extension Hoses
Figure 5-13. Rotary Manifold Hoses
5-10