TM5-3810-305-1016. Prepare crane winch for hoisting as follows:a.b.Never disconnect hydraulic linesor fittings before venting pres-sure. Turn dipstick 1/4 turn tosafety notch to relieve pressure.Failure to follow this procedurecould cause SERIOUS INJURY.Turn dipstick 1/4 turn to safety notch torelieve pressure.Disconnect two winch hoses, tagged H-10and H-11 (Figure 5-13), attached to rotarymanifold with quick disconnect fittings.These hoses come down from winch onc.right side of upperstructure and run inthrough hole to rotary manifold. Reach inand release attaching disconnects on thesehoses.Remove two coiled extension hoses (Fig-ure 5-14) from tool box. Their ends areconnected together by quick disconnects,and are marked with ID tags reading H-10and H-11. Take them to right side ofvehicle.Figure 5-14. Extension HosesFigure 5-13. RotaryManifoldHoses5-10